Keine Abbildung zugeordnet
Keine Abbildung zugeordnet
Keine Abbildung zugeordnet
Keine Abbildung zugeordnet
Keine Abbildung zugeordnet
Keine Abbildung zugeordnet
Keine Abbildung zugeordnet
Keine Abbildung zugeordnet
Keine Abbildung zugeordnet
Keine Abbildung zugeordnet
Keine Abbildung zugeordnet

Polar, Cits500s controlled impedance test system

Polar, Cits500s controlled impedance test system
Artikelnummer: 11099
Beschreibung

The CITS500s Controlled is an impedance test system designed to provide low automated measurement of the resistance characteristic of boards and test coupons.

The resistance test system contains a measurement system controlled by software running in Microsoft Windows software on IBM PC-compatible computers.

The CITS500s is designed to facilitate quick and convenient testing of controlled impedance boards and coupon testing.

Communication between the CITS500s and the Board during the test is achieved with cables, sensors and a microstrip probe.

CITS SOFTWARE is written to run in a Microsoft Windows environment, so the waveform test results can be printed using a printer.

The CITS system can be controlled from a computer keyboard or with simple point-and-click operations with a Microsoft-compatible mouse. Use of the mouse is recommended for maximum convenience.

A footswitch plugin is included in CITS to allow the operator to perform testing.

 

Specification

Test parameters  
The range of the controlled resistance 0 – 150Ω
Measurement accuracy: 1% at 50Ω

 

1.25% at 75Ω

1.5% at 28Ω and 100Ω

(calibrated to 28Ω, 50Ω, 75Ω and 100Ω standards)

The range of acceptable resistance 0.1% – 99.99%
Vertical range (Ω) 1, 2, 5, 10, 20, 50Ω/division
Vertical range (mRho) 10, 20, 50, 100, 200, 500 mRho/division
The horizontal range of the display Automatically installed in the SOFTWARE
Length of the test trace  
Maximum 15 meters
Minimum (without using the probe) 0.09 meters
Minimum (agreed with probe) 0.04 meters
Distance units inches, feet, meters, millimeters
Unit of time nanoseconds, picoseconds
Test method time domain reflectometer (measuring with using software control)
Duration of the reflected pulse front ≤ 200ps
System bandwidth 1.75 GHz (out of maximum build-up)
Output impedance  50Ω (± 2%)
The amplitude of the ripple rated load from 300mV to 50Ω
Calibration method  Calibration for ratiometric measurements

internal accuracy 50Ω
A series of losses compensation 0 – 5Ω/inch
Vp compensation 0.33 – 0.99
Relay 2 x 106 operations / channel (normal value)

 

WORKING ENVIRONMENT CONDITIONS

The appliance is intended for indoor use only under the following environmental conditions.

altitude above sea level Up to 2000m
temperature +10°C to + 30°C indoors
Relative humidity RH maximum 80% at 31 ° C-reduced nominal
linearly up to 50% at 40 ° C
Degree of overvoltage In accordance with the definition of installation Category II
(Overvoltage category II) in IEC 664
Pollution level 2 (IEC664)

 

Power requirements

230V ± 10%, 115V ± 10% or 100V ± 10% at 50/60Hz, 20VA.

Physical characteristics (without additional accessories)
  • temperature
  • indoors 10°C to 30°C
  • Storage 0°C to +50°C
Overall dimensions and weight
  • 443 mm (17.44 in.) width
  • 114 mm (4.48 in.) height
  • 280 mm (11.02 in.) depth
  • weight 5.0 kg (11 lb.)